HLK-1D1215 Energy Module

Hi-Link DC/DC series-1D1215  

Features :  HLK-1D1215 power module

  1. Ultra-miniature standard package SIP package and standard pins
  2. Constant voltage input, isolated unregulated single output, 1W
  3. Input and output isolation withstand voltage 1500VDC
  4. Low ripple/noise (20MH bandwidth) < 100mVp-p

Applications:  HLK-1D1215 power module

  • Can be used in Medical, industrial control, electric power, instrumentation, communication, railway
19 People watching this product now!
Description

HLK-1D1215 12Vdc to 15V mini size dc dc converter customized 

1W series DC-DC power module is one type power supply module with small size, high efficiency, tiny power, constant voltage, input isolation and unregulated, single output; this series of products is specially designed to generate a group of isolated voltage to input power supply in the on-board power system applications. This product is suitable for purely digital circuits, general low-frequency analog circuits, relay drive circuits, data exchange circuits, etc.
Basic Characteristics – HLK-1D1215 power module
  1. Small SIP package
  2. Conversion efficiency 80% (Typ)
  3. Isolation between input and output is required (isolation voltage ≤1500VDC)
  4. No-load input current as low as 5mA
  5. The voltage of the input power supply is relatively stable (voltage variation range ± 10% Vin)
  6. Operating temperature range: -40 ° C ~ + 85 ° C
  7. Output short-circuit protection, low requirements for output voltage stability
  8. Low ripple / noise (20MH bandwidth): 100mVp-p (typ)
  9. International standard pins, PCB board in-line installation
  10. Adopting high-quality environmental protection waterproof and thermally conductive adhesive potting, moisture-proof, vibration-proof, meet the waterproof and dustproof IP65 standard
  11. High reliability, long life design, long continuous working time
Product Features : HLK-1D1215 power module
  1. Ultra-miniature standard package SIP package and standard pins
  2. Constant voltage input, isolated unregulated single output, 1W
  3. Input and output isolation withstand voltage 1500VDC
  4. Low ripple/noise (20MH bandwidth) < 100mVp-p
  5. High efficiency, conversion efficiency up to 80% (MAX)
  6. Operating temperature range: -40°C~+85°C
  7. Good output short circuit and over current protection and self-recovery
  8. High reliability, long life design, MTBF≥3500000H
  9. Potting and sealing with high-quality environmentally friendly waterproof and thermal conductive glue, dustproof, moistureproof, shockproof and flame retardant
  10. Meet UL/CE/EMC and safety testing requirements
  11. It can be used in medical, industrial control, electric power, instrumentation, communication, railway and other fields

Application Notes : HLK-1D1215 power module

  1. Input requirements: ensure that the output voltage fluctuation range of the power supply does not exceed the input requirements of the DC/DC module itself, and the output power of the input power supply must be greater than the output power of the DC/DC module;
  2. Recommended circuit 1: For occasions with general requirements for ripple and noise, a filter capacitor can be connected in parallel to the input and output ends. The external circuit is shown in the above figure (1). The recommended value of the filter capacitor is shown in Table (1) ). Output load requirements: Try to avoid no-load use. When the actual power consumption of the load is less than 10% of the module’s output rated power or there is no-load phenomenon, it is recommended to connect a dummy load to the output end. The dummy load (resistance) can be in accordance with the rated power of the module. 5~10% calculation, resistance value=Uout/(1W*10%);
  3. Overload protection: Under normal working conditions, the output circuit of this product has no protection against overload. The easiest way is to connect a self-recovery fuse in series at the input end, or add a circuit breaker to the circuit;
  4. The capacitance value of the external capacitor at the output end should not be too large, otherwise it will easily cause overcurrent or poor startup when the module starts;
  5. If the product works below the minimum required load, it cannot be guaranteed that the product performance meets all the performance indicators in this manual;
  6. The maximum capacitive load is tested under the input voltage range and full load conditions;
  7. Except for special instructions, all indicators in this manual are measured at Ta=25°C/humidity < 75%RH, nominal input voltage and output rated load;
  8. All index test methods in this product manual are based on our company’s standards;
  9. Our company can provide product customization, and you can directly contact our technical staff for specific information;
  10. Product specifications are subject to change without notice.

Input Characteristic  – HLK-1D1215 power module

Items Working conditions Unit Remarks
Rated input voltage 12 Vdc
Input voltage range 10.8-13.2 Vdc
Max input current ≤0.2 A
Reflected ripple current 15 mA DC12V rated input voltage series
Impulse voltage ≤18 Vdc
Starting voltage 10.8 Vdc
Input undervoltage protection Vdc
Start delay time ms Rated input voltage and constant resistance load
Input filter type Capacitive filtering
Hot plug No-support
Remote end(Ctrl)* Module open
Module closed
Input current when turned off mA

Environment conditions:

Items Technical parameters Unit Remarks
Working temperature -40~+85 ºC
Storage temperature -40~+80 ºC
Relative humidity 5~95 %
Heat dissipation method Natural cooling
Atmospheric pressure 80~106 Kpa
Vibration Vibration coefficient 10~500Hz, 2G10min./1cycle, 60min.each along X,Y,Z axes Meet secondary road transport requirements

1W other types power modules – HLK-1D1215 power module

Model Dimension
(mm)
Output power
(W)
Output voltage
(V)
Output current
(mA)
HLK-1D1205 11.5*10*6 1 5 200
HLK-1D1212 1 12 84
HLK-1D1215 1 15 67
HLK-1D1224 1 24 42